Measuring system
Application range Flow measurement of liquids, gases and vapors
Operating method / measuring principle Float measuring principle
Measured value
Primary measured value Float position
Secondary measured value Operating and standard volumetric flow
Measuring accuracy
Directive VDI / VDE Code 3513 Sheet 2 (q
G
=50%)
DK32 DK34 4.0%
DK37 2.5%
Operating conditions
Max. operating temperature TS -80..+200°C / -112...+392°F
Operating pressure PS Pressure Equipment Directive 97/23/EC
Test pressure PT Pressure Equipment Directive 97/23/EC and AD 2000-HP30
Max. allowable operating pressure PS 130 bar standard 1
Protection category
DK32 / DK34 without cable glands IP66 and IP68
DK32 / DK34 with cable glands IP65
DK37 IP66
Installation conditions
Inlet / outlet run non
1 higher pressures on request