Signal converter for ultrasonic flowmeters
Description of PROFIBUS interface
Description of PROFIBUS interfaceDescription of PROFIBUS interface
Description of PROFIBUS interface
PROFIBUS PA:
PROFIBUS PA:PROFIBUS PA:
PROFIBUS PA:
PROFIBUS device with MBP Physical Interface and PA Profile 3.02 (V2.2.3_ / 140430)
PROFIBUS DP:
PROFIBUS DP:PROFIBUS DP:
PROFIBUS DP:
PROFIBUS device with RS485 Physical Interface and PA Profile 3.02 (V2.2.3_ / 140430)
UFC 400
UFC 400UFC 400
UFC 400
Supplementary instructions
Supplementary instructionsSupplementary instructions
Supplementary instructions
© KROHNE 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en
The documentation is only complete when used in combination with the relevant
documentation for the flow sensor.
Page view 0
1 2 3 4 5 6 ... 55 56

Summary of Contents

Page 1 - UFC 400UFC 400

Signal converter for ultrasonic flowmetersDescription of PROFIBUS interfaceDescription of PROFIBUS interfaceDescription of PROFIBUS interfaceDescripti

Page 2 - CONTENTS

2 PROFIBUS DP 10 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en2.7 Ident. Number selectorWithin a PROFIBUS network the type

Page 3

PROFIBUS DP 211UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enManufacturer specific Ident. Number (4520 hex)This setting provi

Page 4 - SAFETY INSTRUCTIONS

2 PROFIBUS DP 12 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enINFORMATION!During network configuration the user has to defin

Page 5

PROFIBUS DP 213UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enProfile specific Ident. Number (9741 hex)Functionality is reduce

Page 6

2 PROFIBUS DP 14 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en2.9 Baud rateSupported baud rates are listed in the GSD file.

Page 7

PROFIBUS PA 315UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en3.1 Software historyIssued Signal converter Application program

Page 8

3 PROFIBUS PA 16 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en3.2 System configuration of PROFIBUS PA networkThe following

Page 9

PROFIBUS PA 317UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en3.3 Electrical connection for PA signal converterConnection to

Page 10 - PROFIBUS DP

3 PROFIBUS PA 18 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en3.4 Technical dataHardwareType PROFIBUS MBP interface accordi

Page 11 - PROFIBUS DP 2

PROFIBUS PA 319UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en3.5 PROFIBUS PA Profile implementationThe PROFIBUS PA Profile 3

Page 12

CONTENTS 2 www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enUFC 4001 Safety instructions 41.1 Scope of the document...

Page 13

3 PROFIBUS PA 20 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en3.7 Ident. Number selectorWithin a PROFIBUS network the type

Page 14

PROFIBUS PA 321UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enManufacturer specific Ident. Number (4521 hex)This setting provi

Page 15 - PROFIBUS PA 3

3 PROFIBUS PA 22 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enProfile specific Ident. Number (9741 hex)Functionality is redu

Page 16 - PROFIBUS PA

PROFIBUS PA 323UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en3.8 SummaryThe following table shows a summary of the supported

Page 17

4 COMMISSIONING / OPERATION 24 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en4.1 Configuration of cyclic data transferDuring

Page 18

COMMISSIONING / OPERATION 425UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enFormula:Formula:Formula:Formula:value = (-1)VZ * 2

Page 19

4 COMMISSIONING / OPERATION 26 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enThe coding of the status value depends on the ac

Page 20

COMMISSIONING / OPERATION 427UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enStatus = good (Non Cascade)Status = LimitsCheck th

Page 21

4 COMMISSIONING / OPERATION 28 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enClassic StatusClassic StatusClassic StatusClassi

Page 22

COMMISSIONING / OPERATION 429UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enStatus = good (Non Cascade)Status = LimitsCheck th

Page 23

CONTENTS 3www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enUFC 4005 Profibus settings 455.1 Menu A, Quick Setup ...

Page 24 - COMMISSIONING / OPERATION

4 COMMISSIONING / OPERATION 30 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en4.2.2 Output dataOutput data is transferred fro

Page 25 - COMMISSIONING / OPERATION 4

COMMISSIONING / OPERATION 431UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en4.3 DiagnosisThe PROFIBUS device performs interna

Page 26

4 COMMISSIONING / OPERATION 32 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en40 2 Maintenance alarm The device or measurement

Page 27

COMMISSIONING / OPERATION 433UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en65 3 M – Configuration(classification fixed - not

Page 28

4 COMMISSIONING / OPERATION 34 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en76 3 ("S-") Proc: Signal lost(default

Page 29

COMMISSIONING / OPERATION 435UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en1 Indication is supported if Classic Diagnosis is

Page 30

4 COMMISSIONING / OPERATION 36 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enDisplaying "Single events" currently e

Page 31

COMMISSIONING / OPERATION 437UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en4.3.1 Mapping of DIAGNOSIS_EXTENSION bits into DI

Page 32

4 COMMISSIONING / OPERATION 38 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en4 ... X2 I_CONFIG_NO_MEAS_VALUE (82)X1 I_ELECTR_

Page 33

COMMISSIONING / OPERATION 439UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enHow to read the mapping table above:• If e.g. the

Page 34

1 SAFETY INSTRUCTIONS 4 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en1.1 Scope of the documentThese instructions are supple

Page 35

4 COMMISSIONING / OPERATION 40 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en4.3.2 Mapping of DIAGNOSIS_EXTENSION bits into

Page 36

COMMISSIONING / OPERATION 441UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en4 ... X2 I_CONFIG_NO_MEAS_ VALUE (82)X1 I_ELECTR_O

Page 37

4 COMMISSIONING / OPERATION 42 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enHow to read the mapping table above:• If e.g. th

Page 38

COMMISSIONING / OPERATION 443UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enif condensed status and diagnosiscondensed status

Page 39

4 COMMISSIONING / OPERATION 44 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en4.3.4 Filtering of "Single events"As

Page 40

PROFIBUS SETTINGS 545UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enDetailed description of special settings concerning the PR

Page 41

5 PROFIBUS SETTINGS 46 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en5.3 Menu C, Setupif condensed status and diagnosisconde

Page 42

PROFIBUS SETTINGS 547UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enif classic status and diagnosisclassic status and diagnosi

Page 43

5 PROFIBUS SETTINGS 48 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enC4 I/O PROFIBUSC4 I/O PROFIBUS Using the menu functions

Page 44

PROFIBUS SETTINGS 549UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enC5.1 Device InfoC5 DeviceIn this menu all functions are gr

Page 45 - PROFIBUS SETTINGS 5

PROFIBUS DP 25UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en2.1 Software historyThe PROFIBUS DP device has a RS485 interface

Page 46 - PROFIBUS SETTINGS

5 PROFIBUS SETTINGS 50 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en5.4 Menu D, ServiceThis menu is protected. You will nee

Page 47

PROFIBUS SETTINGS 551UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en5.5 Status messages and diagnostic informationError typeE

Page 48

5 PROFIBUS SETTINGS 52 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enM M ElectronicsMem. Life Exceeded The number of maximum

Page 49

NOTES 653UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en

Page 50

6 NOTES 54 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en

Page 51

NOTES 655UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en

Page 52

KROHNE product overview• Electromagnetic flowmeters• Variable area flowmeters• Ultrasonic flowmeters• Mass flowmeters• Vortex flowmeters• Flow control

Page 53 - NOTES 6

2 PROFIBUS DP 6 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en2.3 Electrical connection for DP signal converterI = 110 nHR1

Page 54 - 6 NOTES

PROFIBUS DP 27UFC 400www.krohne.com05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 enI = 110 nHR1 = 390 ΩR2 = 220 ΩI = 110 nHR1 = 390 ΩR2 = 220 ΩExter

Page 55

2 PROFIBUS DP 8 UFC 400www.krohne.com 05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en2.4 Technical dataHardwareType PROFIBUS RS485 interface accord

Page 56 - KROHNE product overview