Installation and
Operating Instructions
LEM 300
Double level control unit
for LS 7000 series
©
KROHNE 02/2006 7.02575.21.00
Subject to change without notice.
Electromagnetic flowmeters
Variable area flowmeters
Mass flowmeters
Ultrasonic flowmeters
Vortex flowmeters
Flow controllers
Level measuring instruments
Pressure and temperature
Heat metering
Communications technology
Switches, counters, displays and recorders
Engineering systems & solutions
Page view 0
1 2 3 4 5 6 ... 10 11

Summary of Contents

Page 1 - Double level control unit

CMDInstallation andOperating InstructionsLEM 300Double level control unitfor LS 7000 series©KROHNE 02/2006 7.02575.21.00Subject to change without not

Page 2 - Contents

10 Installation and Operating Instructions LEM 300 4.5 Example 5 Tank 1 and Tank 2 are being filled with water via Pump 1 and Pump 2. Tank 1: Met

Page 3 - Description

Installation and Operating Instructions LEM 300 11 If you need to return a device for testing or repair to KROHNE Your instrument has been car

Page 4 - 2 Description

2 Installation and Operating Instructions LEM 300 Contents Description...

Page 5 - 3 Technical data

Installation and Operating Instructions LEM 300 3 Description The Double Level Control Unit has two independent, galvanically separated electr

Page 6 - 4.1 Example 1

4 Installation and Operating Instructions LEM 300 1 Safety Instructions This instrument is built and tested according to the specifications and pa

Page 7 - 4.2 Example 2

Installation and Operating Instructions LEM 300 5 3 Technical data Input Range 7...100 KOhm (adjustable) Probe voltage 24 V AC Probe current

Page 8 - 4.3 Example 3

6 Installation and Operating Instructions LEM 300 4 Application Example 4.1 Example 1 A tank is being filled with waste water. Pump 1 is supplying

Page 9 - 4.4 Example 4

Installation and Operating Instructions LEM 300 7 4.2 Example 2 Pump1 is filling a tank to a certain level. The alarm is securing the tank fro

Page 10 - 4.5 Example 5

8 Installation and Operating Instructions LEM 300 4.3 Example 3 A tank is being filled with waste water. Pump 1 is supplying a filter unit. Pump 2

Page 11 - (* delete if not applicable)

Installation and Operating Instructions LEM 300 9 4.4 Example 4 Tank 1 is being filled with water and emptied via a water tap. Security valve1

Comments to this Manuals