Krohne VARIFLUX IFM 6080 K-EEx-i-EEx EN User Manual

Browse online or download User Manual for Equipment Krohne VARIFLUX IFM 6080 K-EEx-i-EEx EN. KROHNE VARIFLUX IFM 6080 K-EEx-i-EEx EN User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Variable area flowmeters
Vortex flowmeters
Flow controllers
Electromagnetic flowmeters
Ultrasonic flowmeters
Mass flowmeters
Level measuring instruments
Communications technology
Engineering systems & solutions
Switches, counters, displays and recorders
Heat metering
Pressure and temperature
© KROHNE 12/2002 7.30917.32.00
Addition to the
installation and operating instructions
ALTOFLUX IFM 4080 K-EEx / i-EEx
PROFIFLUX IFM 5080 K-EEx / i-EEx
VARIFLUX IFM 6080 K-EEx / i-EEx
Compact electromagnetic
flowmeters
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - Compact electromagnetic

Variable area flowmetersVortex flowmetersFlow controllersElectromagnetic flowmetersUltrasonic flowmetersMass flowmetersLevel measuring instrumentsComm

Page 2 - WARNING !

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 10 1.4 IFC 090/…-EEx signal converter The IFC 090/…-EEx signal converter consists o

Page 3 - Contents

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 11 Electrical data of in-/output circuits Terminals Description Nominal voltage Max

Page 4 - 1 System components

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 12 2.3 Connection diagram Flow tube Hazardous locations of Zone 1 and 2E IFS x000…

Page 5

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 13 2.4 Regular IFC 090-EEx electronics unit The field cables that enter the terminal

Page 6 - Temperature classification

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 14 2.5 MODIS version IFC 090i-EEx electronics unit The field cables of the non-intrin

Page 7

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 15 Terminal compartment MODIS version IFC 090i-EEx Sticker with handling informationf

Page 8 - KEMA 02 ATEX 2021 X

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 16 Overview of MODIS modules Module Terminal designation Function / Intrinsically s

Page 9

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 17 The active module DC-I is needed in the 24 Vac/dc power supply version to form an a

Page 10

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 18 For the connection diagrams of the intrinsically safe signal in-/outputs of the in

Page 11 - 2 Electrical connection

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 19 Connection diagrams 1 to 4 of the intrinsically safe signal in-/outputs 1 Cu

Page 12 - OPTION: MODIS

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 2 WARNING ! No changes regarding safety may be made to the devices. Unauthorized chan

Page 13

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 20 Connection diagrams 5 to 8 of the intrinsically safe signal in-/outputs 5 P

Page 14 -  and 0L) must be

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 21 Connection diagrams 9 to 12 of the intrinsically safe signal in-/outputs 9

Page 15 - Insulating cover plate

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 22 3 Operation of the signal converter The i-EEx compact flowmeters are always equipp

Page 16

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 23 5 Service See Sect. 6 or contact your (local) KROHNE sales representative for the o

Page 17

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 24 5.2 Replacement of electronics unit AA Display unit of IFC 090…-EEx Refer to t

Page 18 - Important !

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 25 IFC 090-EEx electronics unit (115/230 Vac version) D D SEDisplay unit (back side)

Page 19 - Version: Ex-i5

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 26 5.3 Replacement of power fuse(s) The power fuse(s) of the different IFC 090…-EEx

Page 20

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 27 Regular IFC 090-EEx with 100…230 Vac power supply Note: Before commencing work, r

Page 21

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 28 MODIS version IFC 090i-EEx Note: Before commencing work, read the instructions in

Page 22 - 4 Maintenance

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 29 5.4 Changing power supply voltage This only applies to the regular IFC 090-EEx ele

Page 23 - 5 Service

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 3 Contents 1 System components 4 1.1 General information ALT

Page 24

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 30 6 Ordering information In case of questions about spare or replacing parts contact

Page 25 - Copper ground strip

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 31 7 Declarations of conformity 7.1 Declaration of conformity of ALTOFLUX IFM 4080

Page 26

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 32 7.2 Declaration of conformity of PROFIFLUX IFM 5080 K / … EEx

Page 27 - Sticker with fuse

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 33 7.3 Declaration of conformity of VARIFLUX IFM 6080 K / … EEx

Page 28 - Fuse_230V

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 34 8 EC-type examination Certificates 8.1 ALTOFLUX IFM 4080 K / … EEx Certificate

Page 29

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 35

Page 30 - 6 Ordering information

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 36

Page 31

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 37

Page 32

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 38

Page 33

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 39

Page 34

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 4 1 System components 1.1 General information ALTOFLUX IFM 4080 K / … EEx This met

Page 35

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 40

Page 36

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 41

Page 37

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 42 8.2 PROFIFLUX IFM 5080 K / … EEx Certificate

Page 38

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 43

Page 39

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 44

Page 40

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 45

Page 41

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 46 8.3 VARIFLUX IFM 6080 K / … EEx Certificate

Page 42

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 47

Page 43

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 48

Page 44

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 49

Page 45

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 5 In case of the MODIS version IFM 4080 K / i-EEx , the electronics unit of type IFC 0

Page 46

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 50

Page 47

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 51

Page 48

AustraliaKROHNE Australia Pty Ltd.Unit 19 No.9, Hudson Ave.Castle Hill 2154, NSWTEL.: +61(0)2-98948711FAX: +61(0)2-98994855e-mail: [email protected].

Page 49

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 6 1.2 General information PROFIFLUX IFM 5080 K / … EEx This compact flowmeter comp

Page 50

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 7 Primary head The IFS 5000-EEx primary head of the IFM 5080 K/…-EEx compact flowmete

Page 51

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 8 1.3 General information VARIFLUX IFM 6080 K / … EEx The compact flowmeter compli

Page 52 - Overseas Representatives

ALTOFLUX IFM x080 K-EEx and ALTOFLUX IFM x080 K / i-EEx 9 Types of protection of primary head Meter size Type of protection DN2.5 up to DN

Comments to this Manuals

No comments