Supplementary Installationand Operating InstructionsBM 100 ABM 100 AiReflex-RadarKEMA 01 ATEX 1078X©KROHNE 10/2001 7.02238.21.00GR/LDVariable area fl
Section 3 - Electrical installationBM 100 A ATEX10/200110• Independent of the type of supply power, the device must be incorporated in the equipotenti
Section 3 - Electrical installation10/2001BM 100 A ATEX113.5 Options, current outputOptions 1 to 7 apply to devices with intrinsically safe outputs (
Section 4 – Initial start-up / Section 5 - OperationBM 100 A ATEX10/200112 ,QLWLDOVWDUWXSDisconnect from power before starting work!Check the foll
Section 6 - Service / Maintenance10/2001BM 100 A ATEX13 6HUYLFHPDLQWHQDQFHThe device has no maintenance requirement when used for the intended pu
Section 6 - Service / MaintenanceBM 100 A ATEX10/2001146.4 MaintenanceMaintenance work of a safety-relevant nature within the meaning of explosion pro
Attachments10/2001BM 100 A ATEX15$WWDFKPHQW 6WDWHPHQWRI&RQIRUPLW\WR,62,(&*XLGH
AttachmentsBM 100 A ATEX10/200116$WWDFKPHQW (&7\SH7HVW&HUWLILFDWH.(0$$7(;;
Attachments10/2001BM 100 A ATEX17
AttachmentsBM 100 A ATEX10/200118
BM 100 A ATEX10/20012&RQWHQWVNameplate 3Range of application 4Product liability and warranty 4General safety information 4Standards / Approvals 41
10/2001BM 100 A ATEX31DPHSODWHSignal converter without intrinsically safe I/O functionNameplate for the version with non-intrinsically safe I/O functi
BM 100 A ATEX10/200145DQJHRIDSSOLFDWLRQThe BM 100 A and BM 100 Ai Reflex-Radar level gauges are designed solely for measuring thedistance, level,vol
Section 1 – Main safety-relevant characteristics10/2001BM 100 A ATEX5 0DLQVDIHW\UHOHYDQWFKDUDFWHULVWLFV1.1 Approved categories1.1.1 1/2 G and 1/
Section 1 – Main safety-relevant characteristicsBM 100 A ATEX10/20016The connected equipment may not exceed the following maximum safety values:I/O fu
Section 1 – Main safety-relevant characteristics10/2001BM 100 A ATEX71.4 Allowable temperatures1.4.1 Process temperatureFor applications requiring Ca
Section 2 - Installation / Section 3 - Electrical installationBM 100 A ATEX10/20018 ,QVWDOODWLRQIn accordance with current installation standards fo
Section 3 - Electrical installation10/2001BM 100 A ATEX9Type of protection EEx di or EEx eiDevices with intrinsically safe I/O functions must be provi