Signal converter for electromagnetic flowmetersElectronic Revision:ER 3.3.xx(SW.REV. 3.3x)IFC 300IFC 300IFC 300IFC 300HandbookHandbookHandbookHandbook
1 SAFETY INSTRUCTIONS 10 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en1.4 Safety instructions from the manufacturer1.4.1 Copyright
4 ELECTRICAL CONNECTIONS 100 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enCurrent input active, Ex i I/Os• Uint, nom = 20 VDC• I ≤ 22
ELECTRICAL CONNECTIONS 4101IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.12.6 HART® connectionHART® connection active (point-to-poi
4 ELECTRICAL CONNECTIONS 102 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enHART® connection passive (Multi-Drop operation)• I: I0% ≥ 4
START-UP 5103IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en5.1 Switching on the powerBefore connecting to power, please check that th
6 OPERATION 104 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en6.1 Display and operating elementsFigure 6-1: Display and operating ele
OPERATION 6105IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en6.1.1 Display in measuring mode with 2 or 3 measured values6.1.2 Display
6 OPERATION 106 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en6.1.3 Display when setting parameters, 4 lines6.1.4 Display when chang
OPERATION 6107IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en6.1.5 Using an IR interface (option)The optical IR interface serves as an
6 OPERATION 108 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en6.2 Menu structureINFORMATION!Note the key function within and between
OPERATION 6109IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enMeasuring mode Select menu↓ ↑Select menu and/or sub-menu↓ ↑Select function
SAFETY INSTRUCTIONS 111IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en1.4.3 Product liability and warrantyThe operator shall bear resp
6 OPERATION 110 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enMeasuring mode Select menu↓ ↑Select menu and/or sub-menu↓ ↑Select functi
OPERATION 6111IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en6.3 Function tables6.3.1 Menu A, quick setupINFORMATION!Depending on the
6 OPERATION 112 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enA4 station address (only for PROFIBUS)A4 station address Setting of devi
OPERATION 6113IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en6.3.2 Menu B, testA7.7 calib. coil temp. The coil temperature is derived
6 OPERATION 114 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enB3.4 flow fraction OnlyOnlyOnlyOnly valid for PF option (partly filled)!
OPERATION 6115IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en6.3.3 Menu C, setupB3.4 SW.REV.UIS User interfaceLC display:1st line: ID
6 OPERATION 116 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enC1.1.8 calib. coil temp. The coil temperature is derived from the coil r
OPERATION 6117IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enC1.2 filterC1.2 filter Grouping of all functions related to filter of meas
6 OPERATION 118 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enC1.3 self testC1.3 self test Grouping of all functions related to self t
OPERATION 6119IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enC1.3.11 limit flow profile NotNotNotNot valid for CAP option (capacitive)
1 SAFETY INSTRUCTIONS 12 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en1.4.5 Warnings and symbols usedSafety warnings are indicated b
6 OPERATION 120 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enC1.5 simulationC1.5 simulation Grouping of all functions for simulating
OPERATION 6121IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enC2. current out XC2. current out X X stands for one of the connection te
6 OPERATION 122 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enC2..15 4mA trimming Trimming of the current at 4 mAReset to 4 mA restor
OPERATION 6123IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enC2.3.11 special functions This function is only available at the terminal
6 OPERATION 124 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enC2.3.11 special functions This function is only available at the pulse o
OPERATION 6125IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enC2. status output XC2. status output X X (Y) stands for one of the conne
6 OPERATION 126 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enC2. limit switch XC2. limit switch X X stands for one of the connectio
OPERATION 6127IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enC2. current input XC2. current input X X stands for connection terminal
6 OPERATION 128 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enNo. Function Settings / descriptionsC3 I/O counterC3.1 counter 1 Set fun
OPERATION 6129IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enNo. Function Settings / descriptionsC4 I/O HARTC4 I/O HARTSelection / disp
DEVICE DESCRIPTION 213IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en2.1 Scope of deliveryINFORMATION!Inspect the cartons carefully fo
6 OPERATION 130 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enC5.2 displayC5.2 display -C5.2.1 language Language selection depends on
OPERATION 6131IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enC5..11 format 3.line Specify decimal places.Select: automatic (adaptation
6 OPERATION 132 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enC5.7 unitsC5.7 units -C5.7.1 volume flow m³/h; m³/min; m³/s; l/h; l/min;
OPERATION 6133IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en6.3.4 Set free unitsC5.8 HARTC5.8 HARTThis function is only available for
6 OPERATION 134 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en6.4 Description of functions6.4.1 Reset counter in the menu "quic
OPERATION 6135IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en6.5 Status messages and diagnostic informationOperational faults in devic
6 OPERATION 136 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enApplication errorF RAM/ROM error IO1 A RAM or ROM error is detected duri
OPERATION 6137IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enMeasurements out of specificationF over range A The current or the corresp
6 OPERATION 138 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enS electrode noise Noise on the electrodes too high. Measured values are
OPERATION 6139IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enInformationMessages on the display Description ActionsStatus: I _ _ _ _ _
2 DEVICE DESCRIPTION 14 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enPossible scope of delivery for signal converter / measuring sens
6 OPERATION 140 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enSimulation of the measured valuesMessages on the display Description Act
SERVICE 7141IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en7.1 Spare parts availabilityThe manufacturer adheres to the basic principle
7 SERVICE 142 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en7.4.2 Form (for copying) to accompany a returned device7.5 DisposalCompa
TECHNICAL DATA 8143IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en8.1 Measuring principleAn electrically conductive fluid flows inside
8 TECHNICAL DATA 144 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en8.2 Technical dataINFORMATION!•The following data is provided for
TECHNICAL DATA 8145IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enOptionsOptionsOptionsOptionsOutputs / inputs Current (incl. HART®), p
8 TECHNICAL DATA 146 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enOperating conditionsTemperatureTemperatureTemperatureTemperaturePro
TECHNICAL DATA 8147IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enMaterialsSignal converter housing StandardStandardStandardStandardVer
8 TECHNICAL DATA 148 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enInputs and outputsGeneral All outputs are electrically isolated fro
TECHNICAL DATA 8149IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enHARTHARTHARTHART®DescriptionHART® protocol via active and passive cur
DEVICE DESCRIPTION 215IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en2.2 Device descriptionElectromagnetic flowmeters are designed exc
8 TECHNICAL DATA 150 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enOperating data Basic I/OsBasic I/OsBasic I/OsBasic I/Os Modular I/O
TECHNICAL DATA 8151IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enStatus output / limit switchStatus output / limit switchStatus output
8 TECHNICAL DATA 152 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enControl inputControl inputControl inputControl inputFunction Hold v
TECHNICAL DATA 8153IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enCurrent inputCurrent inputCurrent inputCurrent inputFunction The foll
8 TECHNICAL DATA 154 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enPROFIBUS DPPROFIBUS DPPROFIBUS DPPROFIBUS DPDescription Galvanicall
TECHNICAL DATA 8155IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enApprovals and certificatesCE The device fulfils the statutory require
8 TECHNICAL DATA 156 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en8.3 Dimensions and weights8.3.1 HousingDimensions and weights in
TECHNICAL DATA 8157IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en8.3.2 Mounting plate, field housingDimensions in mm and inch8.3.3 M
8 TECHNICAL DATA 158 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en8.4 Flow tablesFlow rate in m/s and m3/hQ100 % in m3/hv [m/s] 0.3
TECHNICAL DATA 8159IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enFlow rate in ft/s and US gallons/minQ100 % in US gallons/minv [ft/s]
2 DEVICE DESCRIPTION 16 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en2.2.1 Field housingFigure 2-3: Construction of the field housin
8 TECHNICAL DATA 160 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en8.5 Measuring accuracy (except TIDALFLUX)Reference conditions• Med
TECHNICAL DATA 8161IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en8.6 Measuring accuracy (only TIDALFLUX)The measuring accuracy for pa
8 TECHNICAL DATA 162 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enPartly filled pipesFigure 8-2: Maximum measuring error of measured
DESCRIPTION OF HART INTERFACE 9163IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en9.1 General descriptionThe open HART® protocol, which
9 DESCRIPTION OF HART INTERFACE 164 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en9.3 Connection variantsThe signal converter is a 4-
DESCRIPTION OF HART INTERFACE 9165IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en9.3.1 Point-to-Point connection - analogue / digital
9 DESCRIPTION OF HART INTERFACE 166 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en9.3.2 Multi-Drop connection (2-wire connection)In t
DESCRIPTION OF HART INTERFACE 9167IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en9.3.3 Multi-Drop connection (3-wire connection)Connec
9 DESCRIPTION OF HART INTERFACE 168 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en9.4 Inputs/outputs and HART® dynamic variables and
DESCRIPTION OF HART INTERFACE 9169IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enFor the dynamic variables connected to the linear anal
DEVICE DESCRIPTION 217IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en2.2.2 Wall-mounted housing1 Turn lock to the right and open the
9 DESCRIPTION OF HART INTERFACE 170 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en9.6 Field Communicator 375/475 (FC 375/475)The Fiel
DESCRIPTION OF HART INTERFACE 9171IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en9.7 Asset Management Solutions (AMS)The Asset Managem
9 DESCRIPTION OF HART INTERFACE 172 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en9.8 Field Device Manager (FDM)A Field Device Manage
DESCRIPTION OF HART INTERFACE 9173IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en9.9.2 OperationDue to PDM requirements and convention
9 DESCRIPTION OF HART INTERFACE 174 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en9.10 Field Device Tool / Device Type Manager (FDT /
DESCRIPTION OF HART INTERFACE 9175IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en9.11.1 Overview Basic-DD menu tree (positions in menu
9 DESCRIPTION OF HART INTERFACE 176 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en9.11.2 Basic-DD menu tree (details for settings)1 d
DESCRIPTION OF HART INTERFACE 9177IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4 information 1 liner / 2 electr. material /3 serial n
9 DESCRIPTION OF HART INTERFACE 178 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en3 I/O counter 1 counter 11 funct. of counter Cust/ 2
DESCRIPTION OF HART INTERFACE 9179IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en6 device info1 manufacturer Rd2 model Rd3 device ID Rd
2 DEVICE DESCRIPTION 18 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en2.3 Nameplates2.3.1 Compact version (example)INFORMATION!Look
9 DESCRIPTION OF HART INTERFACE 180 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en9.12 Appendix B: HART® menu tree for AMSAbbreviatio
DESCRIPTION OF HART INTERFACE 9181IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en9.12.2 AMS menu tree (details for settings)Diagnostic
9 DESCRIPTION OF HART INTERFACE 182 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enI/O terminalsA/B/C/Dcurrent output Optrange 0% Cust/
DESCRIPTION OF HART INTERFACE 9183IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enHART identificationmanufacturer Rd/ model Rd/ device I
9 DESCRIPTION OF HART INTERFACE 184 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enProcess Variablesprocess values volume flow / mass f
DESCRIPTION OF HART INTERFACE 9185IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en9.13 Appendix C: HART® menu tree for PDMAbbreviations
9 DESCRIPTION OF HART INTERFACE 186 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enOverview: PDM parameter tableidentification operatio
DESCRIPTION OF HART INTERFACE 9187IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en9.13.2 PDM menu tree (details for settings)Menu Devic
9 DESCRIPTION OF HART INTERFACE 188 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enMenu Viewdisplay volume flow / mass flow / flow spee
DESCRIPTION OF HART INTERFACE 9189IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enPDM parameter tableInformation I counter 1 stopped / I
DEVICE DESCRIPTION 219IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en2.3.2 Remote version (example)Figure 2-6: Example of a nameplate
9 DESCRIPTION OF HART INTERFACE 190 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enI/OI/Oterminals A Cust/ terminals B Cust/ terminals
NOTES 10191IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en
KROHNE product overview• Electromagnetic flowmeters• Variable area flowmeters• Ultrasonic flowmeters• Mass flowmeters• Vortex flowmeters• Flow control
All rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without the prior written authorisation of KROHNE Messtech
2 DEVICE DESCRIPTION 20 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en2.3.3 Electrical connection data of inputs/outputs (example of
INSTALLATION 321IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en3.1 Notes on installation3.2 Storage• Store the device in a dry, dust-
3 INSTALLATION 22 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en3.5 Mounting of the compact version3.6 Mounting the field housing, r
INSTALLATION 323IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en3.6.2 Wall mounting1 Prepare the holes with the aid of the mounting pl
3 INSTALLATION 24 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en3.6.3 Turning the display of the field housing versionThe display of
INSTALLATION 325IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en3.7 Mounting the wall-mounted housing, remote version3.7.1 Pipe mounti
3 INSTALLATION 26 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en3.7.2 Wall mounting1 Prepare the holes with the aid of the mounting
ELECTRICAL CONNECTIONS 427IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.1 Safety instructions4.2 Important notes on electrical con
4 ELECTRICAL CONNECTIONS 28 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.3 Electrical cables for remote device versions, notes4.3.
ELECTRICAL CONNECTIONS 429IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.3.3 Requirements for signal cables provided by the customer
CONTENTS 3www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enIFC 3001 Safety instructions 71.1 Software history ...
4 ELECTRICAL CONNECTIONS 30 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.4 Preparing the signal and field current cables (except T
ELECTRICAL CONNECTIONS 431IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.4.2 Preparing signal cable A, connection to signal converte
4 ELECTRICAL CONNECTIONS 32 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enWall mounted housing• The connection of the outer shield (60
ELECTRICAL CONNECTIONS 433IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.4.3 Length of signal cable AINFORMATION!For temperatures of
4 ELECTRICAL CONNECTIONS 34 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.4.4 Signal cable B (type BTS 300), construction• Signal c
ELECTRICAL CONNECTIONS 435IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en1 Strip the conductor to dimension a. 2 Trim the outer shiel
4 ELECTRICAL CONNECTIONS 36 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enWall-mounted housing• The connection of the outer shield (60
ELECTRICAL CONNECTIONS 437IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.4.6 Length of signal cable BINFORMATION!For temperatures of
4 ELECTRICAL CONNECTIONS 38 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.4.7 Preparing field current cable C, connection to signal
ELECTRICAL CONNECTIONS 439IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enIn the wall-mounted housing version the connection terminals a
CONTENTS 4 www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enIFC 3004.4 Preparing the signal and field current cables (except TIDALFLUX) ...
4 ELECTRICAL CONNECTIONS 40 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.4.8 Preparing signal cable A, connection to measuring sen
ELECTRICAL CONNECTIONS 441IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.4.9 Preparing signal cable B, connection to measuring senso
4 ELECTRICAL CONNECTIONS 42 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.4.10 Preparing field current cable C, connection to measu
ELECTRICAL CONNECTIONS 443IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.5 Connecting the signal and field current cables (except TI
4 ELECTRICAL CONNECTIONS 44 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.5.1 Connecting the signal and field current cables, field
ELECTRICAL CONNECTIONS 445IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.5.2 Connecting the signal and field current cables, wall-mo
4 ELECTRICAL CONNECTIONS 46 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.5.3 Connecting the signal and field current cables, 19&qu
ELECTRICAL CONNECTIONS 447IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.5.4 Connecting the signal and field current cables, 19"
4 ELECTRICAL CONNECTIONS 48 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.5.5 Connection diagram for measuring sensor, field housin
ELECTRICAL CONNECTIONS 449IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.5.6 Connection diagram for measuring sensor, wall-mounted h
CONTENTS 5www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enIFC 3004.12 Connection diagrams of inputs and outputs...
4 ELECTRICAL CONNECTIONS 50 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.5.7 Connection diagram for measuring sensor, 19" rac
ELECTRICAL CONNECTIONS 451IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.5.8 Connection diagram for measuring sensor, 19" rack-
4 ELECTRICAL CONNECTIONS 52 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.6 Preparing and connecting the signal and field current c
ELECTRICAL CONNECTIONS 453IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.6.2 Signal cable A (type DS 300), construction• Signal cabl
4 ELECTRICAL CONNECTIONS 54 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.6.3 Preparing signal cable A, connection to signal conver
ELECTRICAL CONNECTIONS 455IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.6.4 Prepare signal cable A, connect to measuring sensorRequ
4 ELECTRICAL CONNECTIONS 56 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.6.5 Signal cable B (type BTS 300), construction• Signal c
ELECTRICAL CONNECTIONS 457IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en1 Strip the conductor to dimension a. 2 Trim the outer shiel
4 ELECTRICAL CONNECTIONS 58 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.6.7 Preparing signal cable B, connection to measuring sen
ELECTRICAL CONNECTIONS 459IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.6.8 Preparing field current cable C, connection to signal c
CONTENTS 6 www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enIFC 3008.3 Dimensions and weights ...
4 ELECTRICAL CONNECTIONS 60 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.6.9 Preparing field current cable C, connection to measur
ELECTRICAL CONNECTIONS 461IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enAt flow converter side:At flow sensor side:Connecting shieldin
4 ELECTRICAL CONNECTIONS 62 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.6.10 Interface cableThe data interface cable is a shielde
ELECTRICAL CONNECTIONS 463IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.6.11 Connection of cablesFigure 4-35: Electrical connection
4 ELECTRICAL CONNECTIONS 64 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enFlow sensors with protection class IP 68 can not be opened a
ELECTRICAL CONNECTIONS 465IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.7.2 Virtual reference (not valid for TIDALFLUX 4000 & O
4 ELECTRICAL CONNECTIONS 66 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en100...230 VAC (tolerance range: -15% / +10%)100...230 VAC (t
ELECTRICAL CONNECTIONS 467IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enPower supply connection (excluding 19" rack-mounted housi
4 ELECTRICAL CONNECTIONS 68 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.9 Inputs and outputs, overview4.9.1 Combinations of the
ELECTRICAL CONNECTIONS 469IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.9.2 Description of the CG numberThe last 3 digits of the CG
SAFETY INSTRUCTIONS 17IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en1.1 Software historyThe "Electronic Revision" (ER) is c
4 ELECTRICAL CONNECTIONS 70 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.9.3 Fixed, non-alterable input/output versionsThis signal
ELECTRICAL CONNECTIONS 471IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enCG no. Connection terminalsA+ A A- B B- C C- D D-PROFIBUS PA (
4 ELECTRICAL CONNECTIONS 72 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.9.4 Alterable input/output versionsThis signal converter
ELECTRICAL CONNECTIONS 473IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.10 Description of the inputs and outputs4.10.1 Current out
4 ELECTRICAL CONNECTIONS 74 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.10.2 Pulse and frequency output• All outputs are electric
ELECTRICAL CONNECTIONS 475IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.10.3 Status output and limit switch• The status outputs / l
4 ELECTRICAL CONNECTIONS 76 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.10.4 Control input• All control inputs are electrically i
ELECTRICAL CONNECTIONS 477IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.10.5 Current input• All current inputs are electrically iso
4 ELECTRICAL CONNECTIONS 78 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.11 Electrical connection of the inputs and outputs4.11.1
ELECTRICAL CONNECTIONS 479IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.11.2 Wall-mounted housing, electrical connection of the inp
1 SAFETY INSTRUCTIONS 8 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enINFORMATION!In the table below, "x" is a placeholder f
4 ELECTRICAL CONNECTIONS 80 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.11.3 19" rack-mounted housing (28 TE), electrical co
ELECTRICAL CONNECTIONS 481IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.11.4 19" rack-mounted housing (21 TE), electrical conn
4 ELECTRICAL CONNECTIONS 82 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.12 Connection diagrams of inputs and outputs4.12.1 Impor
ELECTRICAL CONNECTIONS 483IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.12.2 Description of the electrical symbolsmA meter0...20 mA
4 ELECTRICAL CONNECTIONS 84 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.12.3 Basic inputs/outputsCurrent output active (HART®), b
ELECTRICAL CONNECTIONS 485IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enPulse/frequency output passive, basic I/Os• Uext ≤ 32 VDC• fma
4 ELECTRICAL CONNECTIONS 86 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enStatus output / limit switch passive, basic I/Os• Uext ≤ 32
ELECTRICAL CONNECTIONS 487IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en4.12.4 Modular inputs/outputs and bus systemsCurrent output a
4 ELECTRICAL CONNECTIONS 88 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enPulse/frequency output active, modular I/Os• Unom = 24 VDC•
ELECTRICAL CONNECTIONS 489IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enPulse/frequency output passive, modular I/Os• Uext ≤ 32 VDC• f
SAFETY INSTRUCTIONS 19IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 en1.2 Intended useThe electromagnetic flowmeters are designed exclu
4 ELECTRICAL CONNECTIONS 90 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enPulse and frequency output passive PN NAMUR, modular I/O• Co
ELECTRICAL CONNECTIONS 491IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enStatus output / limit switch active, modular I/Os• Observe con
4 ELECTRICAL CONNECTIONS 92 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enStatus output / limit switch SN NAMUR, modular I/Os• Any con
ELECTRICAL CONNECTIONS 493IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enControl input active, modular I/Os• Uint = 24 VDC• External co
4 ELECTRICAL CONNECTIONS 94 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enControl input active CN NAMUR, modular I/Os• Connection acc.
ELECTRICAL CONNECTIONS 495IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enCurrent input active, modular I/Os• Uint, nom = 24 VDC• I ≤ 22
4 ELECTRICAL CONNECTIONS 96 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 en4.12.5 Ex i inputs/outputsCurrent output active (only curre
ELECTRICAL CONNECTIONS 497IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enPulse and frequency output passive PN NAMUR, Ex i I/Os• Connec
4 ELECTRICAL CONNECTIONS 98 IFC 300www.krohne.com 08/2010 - 4000069803 - MA IFC 300 R04 enStatus output/limit switch SN NAMUR, Ex i I/Os• Connection a
ELECTRICAL CONNECTIONS 499IFC 300www.krohne.com08/2010 - 4000069803 - MA IFC 300 R04 enControl input passive, Ex i I/Os• 5.5 V ≤ Uext ≤ 32 VDC• Imax