Krohne OPTIFLUX 2070 Quickstart EN User Manual

Browse online or download User Manual for Equipment Krohne OPTIFLUX 2070 Quickstart EN. KROHNE OPTIFLUX 2070 Quickstart EN User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Battery powered electromagnetic flowmeter
OPTIFLUX 2070
Quick Start
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - OPTIFLUX 2070

Battery powered electromagnetic flowmeterOPTIFLUX 2070Quick Start

Page 2 - General safety notes

OPTIFLUX 2070 7309992100 10Torques and pressuresNominal size D N [ m m ]

Page 3 - Scope of delivery

OPTIFLUX 2070www.krohne.com 11Max. torque:• Step 1: approx. 50% of max. torque• Step 2: approx. 80% of max. torque• Step 3: 100% of max. torque give

Page 4 - Inlet and outlet

OPTIFLUX 2070 7309992100 12Terminal assignment of IFC 070

Page 5

OPTIFLUX 2070www.krohne.com 13Electrical values1 Status output 12 Status output 23 Not connected4 Ground5 Pulse output A6 Pulse output BPulse

Page 6 - Magnetic field

OPTIFLUX 2070 7309992100 14Signal and field current cable for remote versionCable connection for field version: flow sensor side• Prepare appropriate

Page 7 - Open discharge

OPTIFLUX 2070www.krohne.com 15• Connect the shield to terminal 1, the purple cable to terminal 2 and the blue to terminal 3.Cable connection for fie

Page 8 - Control valve

OPTIFLUX 2070 7309992100 16• Connect the shield to terminal 1, the purple cable to terminal 2 and the blue to terminal 3.

Page 9 - Grounding

OPTIFLUX 2070www.krohne.com 17Connection of battery• remove the blue protection cap of the converter • remove the 4 Allen bolts (4 mm)• remove the c

Page 10 - Torques and pressures

OPTIFLUX 2070 7309992100 18• tighten the 4 Allen bolts• replace the blue protection capDisplay and operating elementsWARNING!Make sure that the batte

Page 11 - OPTIFLUX 2070

OPTIFLUX 2070www.krohne.com 19Programming• Display test: press Z button 2x 1s• Software version: press Z button 1x 1sNOTE!KROHNE programs the signa

Page 12

OPTIFLUX 2070 7309992100 2General safety notesYou can find the newest and/or additional information on the CD-ROM provided, in the handbook, the data

Page 13 - Electrical values

OPTIFLUX 2070 7309992100 20ContactKROHNE AltometerKROHNE AltometerKROHNE AltometerKROHNE AltometerKerkeplaat 123313 LC DordrechtPostbus 1103300 AC Do

Page 14

OPTIFLUX 2070www.krohne.com 3Visual checkScope of delivery1 OPTIFLUX 2070 with blue protection cap2 Quick Start3 Factory calibration report4 CD-

Page 15

OPTIFLUX 2070 7309992100 4TransportInlet and outlet 1 ≥ 5 DN2 ≥ 2 DN

Page 16

OPTIFLUX 2070www.krohne.com 5Mounting position and flange deviation1 Lmax2 LminCAUTION!Max. permissible deviation of pipe flange faces: Lmax - Lmi

Page 17 - Connection of battery

OPTIFLUX 2070 7309992100 6VibrationMagnetic field

Page 18

OPTIFLUX 2070www.krohne.com 7BendsOpen discharge

Page 19 - Programming

OPTIFLUX 2070 7309992100 8T-sectionControl valve1 ≥ 10 DN

Page 20

OPTIFLUX 2070www.krohne.com 9PumpGrounding1 Metal pipelines, not internally coated. Grounding without grounding rings!2 Metal pipelines with inter