Krohne OPTIMASS with MFC 05x EN User Manual

Browse online or download User Manual for Equipment Krohne OPTIMASS with MFC 05x EN. KROHNE OPTIMASS with MFC 05x EN User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 109
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
©
KROHNE 06/05 7.02233.24.00
Installation and operating
handbook
Optimass Series of Mass Flowmeters and
050/051 Converters
Subject to change without notice
Handbook
Electromagnetic flowmeters
Variable area flowmeters
Mass flowmeters
Ultrasonic flowmeters
Vortex flowmeters
Flow controllers
Level measuring instruments
Pressure and temperature
Heat metering
Communications technology
Switches, counters, displays and recorders
Engineering systems & solutions
Page view 0
1 2 3 4 5 6 ... 108 109

Summary of Contents

Page 1 - Handbook

©KROHNE 06/05 7.02233.24.00Installation and operatinghandbookOptimass Series of Mass Flowmeters and050/051 ConvertersSubject to change without notice

Page 2

Installation and Operating Instructions OPTIMASS 9 1.2 OPTIMASS 7000 Single Straight Tube Meter 1.2.1 Specific Installation Guideline

Page 3 - Contents

Installation and Operating Instructions OPTIMASS 99 6.5 Spares Description Part No Converters Complete Display Ex + Non Ex X2132750100

Page 4

Installation and Operating Instructions OPTIMASS 100 Terminal Labels for MFC 050 Housing Pack of 10 Opt 1: 1 x 4-20 mA, 1 x Pulse, 1 x C

Page 5

Installation and Operating Instructions OPTIMASS 101 7 External Standards and Codes 7.1 Standards The OPTIMASS range of mass flow meters c

Page 6 - Unpacking the meter

Installation and Operating Instructions OPTIMASS 102 7.2 Declaration of Conformity

Page 7 - 1.1 General principles

Installation and Operating Instructions OPTIMASS 103 7.3 PED Certificate

Page 8 - Flow

Installation and Operating Instructions OPTIMASS 104

Page 9

Installation and Operating Instructions OPTIMASS 105 8 Device Configuration sheet The following pages can be photocopied for your use when

Page 10

Installation and Operating Instructions OPTIMASS 106 Notes

Page 11 - Metric PN 40 & PN63

Installation and Operating Instructions OPTIMASS 107 9 Declaration of Cleanliness Certificate Returning a device for testing or repair to

Page 12 - Metric DIN 2501 PN 40

AustraliaKROHNE Australia Pty Ltd Quantum Business Park10/287 Victoria RdRydalmere NSW 2116TEL.: +61 2 8846 1700FAX: +61 2 8846 1755e-mail: krohne@kro

Page 13 - ANSI 150 and 300 lbs

Installation and Operating Instructions OPTIMASS 10 1.2.4 Secondary Pressure containment The OPTIMASS 7000 meters are supplied with se

Page 14

Installation and Operating Instructions OPTIMASS 11 Pressure/Temperature de-rating for SS and Hast. C22Metric DIN 2501 PN 4005101520253

Page 15

Installation and Operating Instructions OPTIMASS 12 Pressure/Temperature de-rating for SS and Hast. C22ANSI 150 and 300 lbs050100150200

Page 16

Installation and Operating Instructions OPTIMASS 13 1.2.6 Hygienic Applications The OPTIMASS 7000 series is available with a variety

Page 17 - Time (hours)

Installation and Operating Instructions OPTIMASS 14 1.2.7 Heating and insulation There are several methods to heat the meter. In most

Page 18

Installation and Operating Instructions OPTIMASS 15 Liquid / Steam heating jacket The meter can be supplied with a heating jacket. This

Page 19

Installation and Operating Instructions OPTIMASS 16 OPTIMASS T10 to T25 - Heating Times 0.0 20.0 40.0 60.0 80.0 100.0 120.0 140.0 160.0

Page 20

Installation and Operating Instructions OPTIMASS 17 OPTIMASS H & S 40 Heating Time 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.

Page 21

Installation and Operating Instructions OPTIMASS 18 1.2.8 Purge Port Meters and Burst Disk Meters Purge Port Options If the purge port

Page 23

Installation and Operating Instructions OPTIMASS 19 1.2.9 Technical Data Nominal Flow Rates 06 10 15 25 40 50 80 Kg/h 950 2,700 1

Page 24

Installation and Operating Instructions OPTIMASS 20 1.2.10 Weights & Dimensions Weights Weight of OPTIMASS 7000 sensor fitted

Page 25

Installation and Operating Instructions OPTIMASS 21 Meter connection size Connection type Connection standard D in mm D in inches

Page 26

Installation and Operating Instructions OPTIMASS 22 Heating Jacket Dimensions Titanium Hastelloy HJ Meter Size Connection Size ø A

Page 27 - JACKET CONNECTION

Installation and Operating Instructions OPTIMASS 23 1.3 OPTIMASS 3000 (7100) Single Z Shaped Tube Meter 1.3.1 Specific Installation Gui

Page 28

Installation and Operating Instructions OPTIMASS 24 Flanged and Tri-clamp Meters When installing these meters ensure that the pipework is

Page 29

Installation and Operating Instructions OPTIMASS 25 1.3.4 Secondary Pressure containment The OPTIMASS 3000 (7100) meters are supplied wi

Page 30

Installation and Operating Instructions OPTIMASS 26 1.3.6 Heating and insulation All secondary containment and heated jacket parts are 3

Page 31

Installation and Operating Instructions OPTIMASS 27 1.3.8 Technical Data Nominal Flow Rates 01 03 04 Kg/h 15 100 350 Lbs/min 0.5 3.5

Page 32

Installation and Operating Instructions OPTIMASS 28 1.3.9 Weights & Dimensions Weights Weight of OPTIMASS 3000 (7100) sensor fitt

Page 33 - Flange JIS B 2220 20K

Installation and Operating Instructions OPTIMASS 2 Contents 1 MECHANICAL INSTALLATION 6 1.1 General principles 6 1.1.1 Transport and Liftin

Page 34

Installation and Operating Instructions OPTIMASS 29 Dimensions 7100 Flange Size ø A B std B Ex C None 256 104 120 N/A ANSI 150 2

Page 35

Installation and Operating Instructions OPTIMASS 30 1.4 OPTIMASS 8000 / 9000 Meter with Twin U Measuring Tubes 1.4.1 Specific Installa

Page 36

Installation and Operating Instructions OPTIMASS 31 1.4.4 Secondary Pressure containment The OPTIMASS 8000/9000 series sensors do not ha

Page 37

Installation and Operating Instructions OPTIMASS 32 ANSI flanges to ASME B16.5. Note also pressure / temperature limits for measuring tu

Page 38

Installation and Operating Instructions OPTIMASS 33 1.4.6 Hygienic Applications The OPTIMASS 8000/9000 series is available with a vari

Page 39

Installation and Operating Instructions OPTIMASS 34 1.4.7 Heating and insulation Insulation OPTIMASS 8000 Where insulation is required

Page 40 - 2.2 Connection to power

Installation and Operating Instructions OPTIMASS 35 1.4.8 Purge Port Meters and Burst Disk Meters Purge Port Options If the purge port o

Page 41

Installation and Operating Instructions OPTIMASS 36 Flanged & Hygienic Connections Dimension A SIZE 15 SIZE 25 SIZE 40 SIZE 80

Page 42 - 2.5 Inputs and outputs

Installation and Operating Instructions OPTIMASS 37 Triclamp DIN32676 & ISO2852 Material SIZE 15 SIZE 25 SIZE 40 SIZE 80

Page 43

Installation and Operating Instructions OPTIMASS 38 Insulated / Heated Jacket Meters Major external dimensions of insulating and hea

Page 44

Installation and Operating Instructions OPTIMASS 3 4 PROGRAMMING THE CONVERTER MFC 050/051 52 4.1 Operating and check elements 52 4.2 OP

Page 45

Installation and Operating Instructions OPTIMASS 39 2 Electrical Installation 2.1 Location and connecting cables Location Do not expose

Page 46

Installation and Operating Instructions OPTIMASS 40 2.2.3 Power Supply Wiring MFC 051 Ex Slide the cover to the left to expose the po

Page 47 - Option Function

Installation and Operating Instructions OPTIMASS 41 Shield is connected through the cable gland. 2.4 Hazardous Area requirements • H

Page 48

Installation and Operating Instructions OPTIMASS 42 Output Option 1 Active status O/P 24V DC Pulse O/P (Passive) Input < 24V

Page 49 - 2.7 Technical Data

Installation and Operating Instructions OPTIMASS 43 Input <24V DC 0V DC Contact Fig 5 : Binary input Fig 6 : Bin

Page 50

Installation and Operating Instructions OPTIMASS 44 Output Option 2 Modbus Current Output Refer to communications handbook

Page 51 - 3.2 Initial Start-up

Installation and Operating Instructions OPTIMASS 45 Output Option 5 Status Output (Passive) Control Input (Passive) Current Out

Page 52 - KROHNE MFC 50

Installation and Operating Instructions OPTIMASS 46 2.5.2 Inputs / Outputs MFC051 The MFC 051 offers galvanically separated outputs in

Page 53 - KROHNE MFC 50

Installation and Operating Instructions OPTIMASS 47 Output Option 3 In addition to the 1st 4...20mA, a control or binary input can be w

Page 54

Installation and Operating Instructions OPTIMASS 48 2.6 Compact to Remote / Remote to Compact conversion instructions Conversion of the

Page 55 - 4.3 Key functions

Installation and Operating Instructions OPTIMASS 4 How to use these installation and operating instructions Congratulations on purchasing

Page 56

Installation and Operating Instructions OPTIMASS 49 2.7.2 MFC051 Power Supply Operating Voltage : 100 – 230V AC (+10% / -15%) 24V DC

Page 57

Installation and Operating Instructions OPTIMASS 50 3 Start-Up 3.1 Factory Set Parameters The mass flow meter leaves the factory ready

Page 58

Installation and Operating Instructions OPTIMASS 51 3.3 Zero point adjustment After installation adjust the zero point. To do this, the

Page 59

Installation and Operating Instructions OPTIMASS 52 4 Programming the Converter MFC 050/051 4.1 Operating and check elements The opera

Page 60

Installation and Operating Instructions OPTIMASS 53 4.2 OPTIMASS MFC 050/051 Operating Concept

Page 61

Installation and Operating Instructions OPTIMASS 54 4.3 Key functions Function of the keys Cursor The location of the cursor on the dis

Page 62

Installation and Operating Instructions OPTIMASS 55 4.3.1 How to enter programming mode To start: Display Comments → Press Fct. 1 OPERA

Page 63

Installation and Operating Instructions OPTIMASS 56 Examples The cursor (flashing part of display) has a grey background in the following

Page 64

Installation and Operating Instructions OPTIMASS 57 To change numeric values Increase numeric value

Page 65

Installation and Operating Instructions OPTIMASS 58 4.4 Table of programmable functions Fct. No Text Description and settings 1 OPERAT

Page 66

Installation and Operating Instructions OPTIMASS 5 Unpacking the meter When unpacking your meter, please ensure that no visible damage has oc

Page 67

Installation and Operating Instructions OPTIMASS 59 Fct. No Text Description and settings 2 TEST Main Menu 2. Test functions 2.1 DISPL

Page 68

Installation and Operating Instructions OPTIMASS 60 Fct. No Text Description and settings 3 CONFIG Main menu 3 Configuration 3.1 BASIS

Page 69 - 5 Description of Functions

Installation and Operating Instructions OPTIMASS 61 Fct. No Text Description and settings 3.2.11 CONC.BY.VOL. Monitor concentration by v

Page 70

Installation and Operating Instructions OPTIMASS 62 Fct. No Text Description and settings 4 I.O. CONFIG Main menu 4 Input/output config

Page 71

Installation and Operating Instructions OPTIMASS 63 Fct. No Text Description and settings 4.5 PULSE OUT. Submenu 4.5 Pulse/frequency ou

Page 72

Installation and Operating Instructions OPTIMASS 64 Fct. No Text Description and settings 4.6 ALARM. OUT Sub menu 4.6 Process alarm out

Page 73

Installation and Operating Instructions OPTIMASS 65 Fct. No Text Description and settings 4.8 SYS.CTROL Submenu 4.8 System control 4.8.

Page 74

Installation and Operating Instructions OPTIMASS 66 Fct. No Text Description and settings 5 FACTORY.SET Main menu 5 Factory settings 5.

Page 75

Installation and Operating Instructions OPTIMASS 67 4.5 Reset / Quit Menu - Totalizer reset and status indication acknowledgement Total

Page 76

Installation and Operating Instructions OPTIMASS 68 5 Description of Functions In all the following examples, a short notation is used

Page 77

Installation and Operating Instructions OPTIMASS 6 1 Mechanical Installation 1.1 General principles The OPTIMASS mass flow meters pro

Page 78

Installation and Operating Instructions OPTIMASS 69 Under certain conditions, it may not be possible to adjust the zero point, for insta

Page 79

Installation and Operating Instructions OPTIMASS 70 Note: When changing from STOP into STANDBY the instrument will run through the START

Page 80

Installation and Operating Instructions OPTIMASS 71 First (1st) Entered Sample Option: CAL Sample 1 Exit - Do not calibrate and exit (Do

Page 81

Installation and Operating Instructions OPTIMASS 72 Density of water as a function of temperature Temperature in Density in Tempera

Page 82

Installation and Operating Instructions OPTIMASS 73 Temperature in Density in Temperature in Density in °C °F kg/m3 lb/ft3 °C °F

Page 83

Installation and Operating Instructions OPTIMASS 74 5.2 Menu 2 – Functional Checks Menu 2.0. contains a number of test functions. These

Page 84

Installation and Operating Instructions OPTIMASS 75 Testing the pulse output Fct. 2.5 To test the pulse output, connect an external co

Page 85

Installation and Operating Instructions OPTIMASS 76 Testing alarm output Fct. 2.7 This is a simple function that allows the alarm outp

Page 86

Installation and Operating Instructions OPTIMASS 77 Viewing sensor signal conditions – Diagnose Fct. 2.9 Menu 2.9 allows the viewin

Page 87

Installation and Operating Instructions OPTIMASS 78 5.3 Menu 3- Configuration Menu To access this menu, enter programming mode Display

Page 88

Installation and Operating Instructions OPTIMASS 7 Examples Vertical mounting Horizontal mounting Upward sloping installa

Page 89

Installation and Operating Instructions OPTIMASS 79 To set a time constant: e.g. 0.5 sec Display Key Line 1 Line 2 From 3.1.(2) Time

Page 90

Installation and Operating Instructions OPTIMASS 80 Flow direction Fct. 3.1.4 This function allows the user to select the direction of

Page 91

Installation and Operating Instructions OPTIMASS 81 Pressure Suppression Fct. 3.1.8 and 3.1.9 The Pressure Suppression feature eliminate

Page 92

Installation and Operating Instructions OPTIMASS 82 Cyclic Display Fct. 3.2.1 The display can be programmed to cycle between all values

Page 93

Installation and Operating Instructions OPTIMASS 83 Volume Total Fct. 3.2.5. Parameters for the volume totalizer are selected in this m

Page 94 - 6.1 Diagnostic functions

Installation and Operating Instructions OPTIMASS 84 Velocity: Fct. 3.2.12 This function provides an additional measurement parameter. T

Page 95 - 6.2 Error Messages

Installation and Operating Instructions OPTIMASS 85 Menu 3.5 Passwords This menu contains all the settings to protect the configurati

Page 96

Installation and Operating Instructions OPTIMASS 86 Menu 3.6 Settings This menu allows a Tag or ID number to be programmed. A combinatio

Page 97

Installation and Operating Instructions OPTIMASS 87 Range Fct. 4.2.2. This allows the setting of the measurement range of the output.

Page 98

Installation and Operating Instructions OPTIMASS 88 Alarm Output – Menu 4.6 Function Fct. 4.6.1. Any one of the following may be progr

Page 99

Installation and Operating Instructions OPTIMASS 8 1.1.1 Transport and Lifting As the larger meters are heavy, care should be taken whe

Page 100 - 6.5 Spares

Installation and Operating Instructions OPTIMASS 89 System Control – Menu 4.8 This menu allows the setting up of certain instrument fun

Page 101

Installation and Operating Instructions OPTIMASS 90 Calibration – Menu 4.10 This menu allows the calibration of the current outputs. Thi

Page 102 - 7.1 Standards

Installation and Operating Instructions OPTIMASS 91 5.5 Menu 5 - Factory Settings This menu allows the user to view certain informati

Page 103 -

Installation and Operating Instructions OPTIMASS 92 Serial numbers – Menu 5.5 All the components that make up the complete instrument ha

Page 104 - 7.3 PED Certificate

Installation and Operating Instructions OPTIMASS 93 6 Service and Trouble Shooting 6.1 Diagnostic functions The following diagnostic fu

Page 105

Installation and Operating Instructions OPTIMASS 94 6.2 Error Messages • Basic Errors: These errors are displayed independently of which

Page 106

Installation and Operating Instructions OPTIMASS 95 6.3 Functional Tests and Troubleshooting Min. and Max. recorded temperature (menu 5.

Page 107

Installation and Operating Instructions OPTIMASS 96 Zero Problems • Perform auto zero, observe the displayed value, it should be stable

Page 108

Installation and Operating Instructions OPTIMASS 97 OPTIMASS 8000 / 9000 Inductance (mH) Resistance (Ohm) OPTIMASS Driver Sensor A/B

Page 109

Installation and Operating Instructions OPTIMASS 98 6.4.2 Replacing the Back End Unscrew the front lid and undo the two screws holding t

Comments to this Manuals

No comments