Ultrasonic gas flowmeterOPTISONIC 7300OPTISONIC 7300OPTISONIC 7300OPTISONIC 7300HandbookHandbookHandbookHandbook© KROHNE 09/2012 - 4001102303 - MA OPT
2 DEVICE DESCRIPTION 10 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en2.1 Scope of deliveryINFORMATION!Do a check of th
8 TECHNICAL DATA 100 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enLow-flow cutoffLow-flow cutoffLow-flow cutoffLow-flow
TECHNICAL DATA 8101OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enFOUNDATION FieldbusFOUNDATION FieldbusFOUNDATION Fieldb
8 TECHNICAL DATA 102 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en8.3 Dimensions and weightsRemote versionRemote versi
TECHNICAL DATA 8103OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en8.3.1 Gas flow sensor, carbon steelEN 1092-1Nominal si
8 TECHNICAL DATA 104 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enASME 150 lbASME 300 lbNominal sizeDimensions Approx w
TECHNICAL DATA 8105OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enASME 600 lbASME 900 lbNominal sizeDimensions [inches] A
8 TECHNICAL DATA 106 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en8.3.2 Converter housingDimensions and weights in mm
TECHNICAL DATA 8107OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en8.3.3 Mounting plate, field housingDimensions in mm an
9 DESCRIPTION OF HART INTERFACE 108 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.1 General descriptionThe open HART®
DESCRIPTION OF HART INTERFACE 9109OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.3 Connection variantsThe signal conve
DEVICE DESCRIPTION 211OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en2.2 Device descriptionThe ultrasonic flowmeters are
9 DESCRIPTION OF HART INTERFACE 110 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.3.1 Point-to-Point connection - ana
DESCRIPTION OF HART INTERFACE 9111OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.3.2 Multi-Drop connection (2-wire con
9 DESCRIPTION OF HART INTERFACE 112 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.3.3 Multi-Drop connection (3-wire c
DESCRIPTION OF HART INTERFACE 9113OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.4 Inputs/outputs and HART® dynamic va
9 DESCRIPTION OF HART INTERFACE 114 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.5 Remote operationIn addition to th
DESCRIPTION OF HART INTERFACE 9115OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.5.2 Parameters for the basic configur
9 DESCRIPTION OF HART INTERFACE 116 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.6.2 OperationThe Field Communicator
DESCRIPTION OF HART INTERFACE 9117OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.7 Asset Management Solutions (AMS)The
9 DESCRIPTION OF HART INTERFACE 118 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.8 Process Device Manager (PDM)The P
DESCRIPTION OF HART INTERFACE 9119OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.9 Field Device Manager (FDM)A Field D
2 DEVICE DESCRIPTION 12 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en2.2.1 Field housingFigure 2-2: Construction of th
9 DESCRIPTION OF HART INTERFACE 120 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.11 HART Menu Tree9.11.1 HART Menu
DESCRIPTION OF HART INTERFACE 9121OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.11.2 HART Menu Tree AMS - Device&apos
9 DESCRIPTION OF HART INTERFACE 122 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.11.3 HART Menu Tree PDM - Menu Bar
DESCRIPTION OF HART INTERFACE 9123OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.11.4 HART Menu Tree FDM - Device Conf
9 DESCRIPTION OF HART INTERFACE 124 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.11.6 Process Variables Root MenuMea
DESCRIPTION OF HART INTERFACE 9125OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.11.7 Diagnostic Root MenuStatusStanda
9 DESCRIPTION OF HART INTERFACE 126 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enSimulationProcess Input <Simulation
DESCRIPTION OF HART INTERFACE 9127OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.11.8 Device Root MenuQuick SetupQuick
9 DESCRIPTION OF HART INTERFACE 128 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enStatus Output A/B/C/D OptMode / Output
DESCRIPTION OF HART INTERFACE 9129OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enHARTHARTHARTRd/ Online Mode?Loc/ <Pre
DEVICE DESCRIPTION 213OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en2.3 Nameplates2.3.1 Example of nameplate for the c
9 DESCRIPTION OF HART INTERFACE 130 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en9.11.9 Offline Root MenuIdentificatio
DESCRIPTION OF HART INTERFACE 9131OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enLimit Switch A/B/C/D OptMeasurement / Th
9 DESCRIPTION OF HART INTERFACE 132 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enServiceServiceServiceServiceService Ac
NOTES 10133OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en
10 NOTES 134 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en
NOTES 10135OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en
KROHNE product overview• Electromagnetic flowmeters• Variable area flowmeters• Ultrasonic flowmeters• Mass flowmeters• Vortex flowmeters• Flow control
2 DEVICE DESCRIPTION 14 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en2.3.2 Example of nameplate for the measuring sens
DEVICE DESCRIPTION 215OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enElectrical connection data of inputs/outputs (exampl
3 INSTALLATION 16 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en3.1 Notes on installation3.2 Storage• Store the device
INSTALLATION 317OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en3.3 TransportSignal converter• Do not lift the signal con
3 INSTALLATION 18 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en3.5.1 Inlet and outlet3.5.2 Mounting position• Horizon
INSTALLATION 319OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en3.5.3 Flange deviation3.5.4 T-sectionFigure 3-5: Horizon
All rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without the prior written authorisation of KROHNE Messtech
3 INSTALLATION 20 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en3.5.5 Vibration3.5.6 Control valveTo avoid distorted f
INSTALLATION 321OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en3.6 Mounting the field housing, remote version3.6.1 Pipe
3 INSTALLATION 22 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en3.6.2 Turning the display of the field housing versionT
ELECTRICAL CONNECTIONS 423OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.1 Safety instructions4.2 Signal cable (remot
4 ELECTRICAL CONNECTIONS 24 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enCAUTION!To ensure smooth functioning, always u
ELECTRICAL CONNECTIONS 425OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.3 Power supply100…230 VAC• Connect the protec
4 ELECTRICAL CONNECTIONS 26 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.4 Laying electrical cables correctly1 Lay
ELECTRICAL CONNECTIONS 427OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.5 Inputs and outputs, overview4.5.1 Combinat
4 ELECTRICAL CONNECTIONS 28 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.5.2 Description of the CG numberThe last 3
ELECTRICAL CONNECTIONS 429OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.5.3 Fixed, non-alterable input/output version
CONTENTS 3www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enOPTISONIC 73001 Safety instructions 61.1 Intended use ...
4 ELECTRICAL CONNECTIONS 30 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.5.4 Alterable input/output versionsThis sig
ELECTRICAL CONNECTIONS 431OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.6 Description of the inputs and outputs4.6.1
4 ELECTRICAL CONNECTIONS 32 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.6.2 Current output• All outputs are electri
ELECTRICAL CONNECTIONS 433OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.6.3 Pulse and frequency output• All outputs a
4 ELECTRICAL CONNECTIONS 34 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.6.4 Status output and limit switch• The sta
ELECTRICAL CONNECTIONS 435OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.6.5 Control input• All control inputs are ele
4 ELECTRICAL CONNECTIONS 36 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.7 Connection diagrams of inputs and outputs
ELECTRICAL CONNECTIONS 437OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.7.2 Description of the electrical symbolsmA m
4 ELECTRICAL CONNECTIONS 38 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.7.3 Basic inputs/outputsCurrent output acti
ELECTRICAL CONNECTIONS 439OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enPulse/frequency output passive, basic I/Os• Uext
CONTENTS 4 www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enOPTISONIC 73004.5.4 Alterable input/output versions...
4 ELECTRICAL CONNECTIONS 40 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enStatus output / limit switch passive, basic I/
ELECTRICAL CONNECTIONS 441OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.7.4 Modular inputs/outputs and bus systemsCur
4 ELECTRICAL CONNECTIONS 42 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enPulse/frequency output active, modular I/Os• U
ELECTRICAL CONNECTIONS 443OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enPulse/frequency output passive, modular I/Os• Ue
4 ELECTRICAL CONNECTIONS 44 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enPulse and frequency output passive PN NAMUR, m
ELECTRICAL CONNECTIONS 445OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enStatus output / limit switch active, modular I/O
4 ELECTRICAL CONNECTIONS 46 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enStatus output / limit switch SN NAMUR, modular
ELECTRICAL CONNECTIONS 447OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enControl input passive, modular I/Os• 3V≤ Uext ≤
4 ELECTRICAL CONNECTIONS 48 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enCurrent input active, modular I/Os• Uint, nom
ELECTRICAL CONNECTIONS 449OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.7.5 Ex i inputs/outputsCurrent output active
CONTENTS 5www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enOPTISONIC 73008 Technical data 908.1 Measuring principle...
4 ELECTRICAL CONNECTIONS 50 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enPulse and frequency output passive PN NAMUR, E
ELECTRICAL CONNECTIONS 451OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enStatus output/limit switch SN NAMUR, Ex i I/Os•
4 ELECTRICAL CONNECTIONS 52 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enControl input passive, Ex i I/Os• 5.5 V ≤ Uext
ELECTRICAL CONNECTIONS 453OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enCurrent input active, Ex i I/Os• Uint, nom = 20
4 ELECTRICAL CONNECTIONS 54 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en4.7.6 HART® connectionHART® connection active
ELECTRICAL CONNECTIONS 455OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enHART® connection passive (Multi-Drop mode)• I: I
5 START-UP 56 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en5.1 Switching on the powerBefore connecting to power, pleas
OPERATION 657OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.1 Display and operating elementsFigure 6-1: Display and op
6 OPERATION 58 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enKey Measuring mode Menu mode Submenu or function modeParame
OPERATION 659OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.1.1 Display in measuring mode with 2 or 3 measured values6
1 SAFETY INSTRUCTIONS 6 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en1.1 Intended useThe overall functionality of the
6 OPERATION 60 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.1.3 Display when setting parameters, 4 lines6.1.4 Displ
OPERATION 661OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.1.5 Using an IR interface (option)The optical IR interface
6 OPERATION 62 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.2 Menu overviewMeasuring mode Select menuSelect menu and
OPERATION 663OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enMeasuring mode Select menuSelect menu and/or sub-menu Select
6 OPERATION 64 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enMeasuring mode Select menuSelect menu and/or sub-menu Selec
OPERATION 665OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.3 Function tables6.3.1 Menu A, quick setupINFORMATION!• T
6 OPERATION 66 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.3.2 Menu B, testNo.No.No.No. FunctionFunctionFunctionFun
OPERATION 667OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enactual valuesB2 actual values Display the current values; exi
6 OPERATION 68 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.3.3 Menu C, setupNo.No.No.No. FunctionFunctionFunctionFu
OPERATION 669OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC1.5.2 velocity of sound Query: sim. velocity of sound.Select
SAFETY INSTRUCTIONS 17OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en1.3 Safety instructions from the manufacturer1.3.1
6 OPERATION 70 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC1.13 temperature Only available if ‘fixed’ is selected in
OPERATION 671OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC2..4 range Terminal ARange: 1.00…250.00 bara asumes absolut
6 OPERATION 72 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC2..4 error condition The following error conditions can b
OPERATION 673OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enfrequency output XC2. frequency output X X stands for one of
6 OPERATION 74 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC2..11 phase shift w.r.t. B Only available when configurin
OPERATION 675OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC2..9 invert signal Select:Off (activated output generates a
6 OPERATION 76 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC2..2 limit switch Y and control input YOnly appears if ou
OPERATION 677OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC2..1 mode Off (control input switched off)Hold all outputs
6 OPERATION 78 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC3..7 set counter Set counter to the desired value.Selec
OPERATION 679OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC5.1.4 electronic serial no. Serial no. of the electronic ass
1 SAFETY INSTRUCTIONS 8 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en1.3.3 Product liability and warrantyThe operator
6 OPERATION 80 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC5..7 format 1.line Specify decimal places.Select: automat
OPERATION 681OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC5.6.3 load settings Load saved settings.Select: cancel (exit
6 OPERATION 82 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC5.7.16 volumeCf; m3; L; ext. unit selection (activates opt
OPERATION 683OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.3.4 Set free unitsFree units Sequences to set texts and fa
6 OPERATION 84 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.4 Description of functions6.4.1 Reset counter in the me
OPERATION 685OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en6.5 Error messagesError Error Error Error codecodecodecodeGr
6 OPERATION 86 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enF application errorApplication-dependent error of the compl
OPERATION 687OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enC simulation VoS Sensor electronics simulates measurement of
7 SERVICE 88 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en7.1 Spare parts availabilityThe manufacturer adheres to the
SERVICE 789OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en7.3.2 Form (for copying) to accompany a returned device7.4 Di
SAFETY INSTRUCTIONS 19OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en1.3.5 Warnings and symbols usedSafety warnings are
8 TECHNICAL DATA 90 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en8.1 Measuring principle• Like canoes crossing a river
TECHNICAL DATA 891OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 en8.2 Technical dataINFORMATION!•The following data is pr
8 TECHNICAL DATA 92 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enDisplay and user interfaceDisplay and user interfaceDi
TECHNICAL DATA 893OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enPressurePressurePressurePressureAll sensor designs at fu
8 TECHNICAL DATA 94 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enTube transducer cabling, caps transducer holderStainle
TECHNICAL DATA 895OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enInputs and outputsGeneral All in-and outputs are galvan
8 TECHNICAL DATA 96 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enHARTHARTHARTHART®Description HART® protocol via active
TECHNICAL DATA 897OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enPassive Uext ≤ 32 VDC -fmax in operating menu set to:
8 TECHNICAL DATA 98 OPTISONIC 7300www.krohne.com 09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enStatus output / limit switchStatus output / limit swit
TECHNICAL DATA 899OPTISONIC 7300www.krohne.com09/2012 - 4001102303 - MA OPTISONIC 7300 R03 enControl inputControl inputControl inputControl inputFunc
Comments to this Manuals