Operating InstructionsOPTISWITCH 3100 Cwith contactless electronic switch
4 Mounting4.1 General instructionsIn general, OPTISWITCH 3100 C can be mounted in anyposition. The instrument must be mounted in such a way thatthe vi
The vibrating level switch is a measuring instrument and mustbe treated accordingly. Bending the vibrating element willdestroy the instrument.Warning:
In abrasive solids, mounting according to illustration b. hasproven. A spout forms in the concave protective sheetpreventing wear of the protective sh
12Fig. 5: Orientation of the tuning fork in case of flow1 Marking with screwed version2 Direction of flowIn case of horizontal mounting in adhesive prod
>125Fig. 7: Baffle protection against damages14 OPTISWITCH 3100 C - with contactless electronic switchMounting29952-EN-060830
5 Connecting to voltage supply5.1 Preparing the connectionGenerally not the following safety instructions:l Connect only in the complete absence of li
1 Unscrew the housing cover2 Loosen compression nut of the cable entry3 Remove approx. 10 cm (4 in) of the cable mantle, stripapprox. 1 cm (0.4 in) in
14442 3Fig. 9: Material versions, single chamber housing1 Plastic (not with EExd)2 Aluminium3 Stainless steel (not with EExd)4 Filter element for pres
the electronics would be destroyed if connected directly to themains. It is not suitable for connection to low voltage PLCinputs.Domestic current is t
6 Set up6.1 GeneralThe numbers in brackets refer to the following illustrations.On the electronics module you will find the following indicatingand adj
Contents1 About this document1.1 Function ...41.2 Target group ...41.3 Symbolism used ...
With the potentiometer you can adapt the switching point to thesolid. It is already preset and must only be modified in specialcases.By default, the po
Level Switching status Control lampMode min.Dry run protection21Switch closed GreenMode min.Dry run protection21Switch open redFailure of the supply v
7 Maintenance and fault rectification7.1 MaintenanceWhen used as directed in normal operation, OPTISWITCH3100 C is completely maintenance free.7.2 Rect
l Wrong mode selectedà Set the correct mode on the mode switch (max.: overfillprotection; min.: dry run protection). Wiring should becarried out accord
6 Remove the old oscillator7 Compare the new oscillator with the old one. The type labelof the oscillator must correspond to that of the oldoscillator
8 Dismounting8.1 Dismounting procedureWarning:Before dismounting, be aware of dangerous process con-ditions such as e.g. pressure in the vessel, high
9 Supplement9.1 Technical dataGeneral dataMaterial 316L corresponds to 1.4404 or 1.4435Materials, wetted parts- Process fitting - thread 316L- Process
Process pressure -1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psi)6 bar(87psi)-50˚C(-58˚F)16 bar(232psi)50˚C(122˚F)100˚C(212˚F)0˚C(32˚F)150˚C(302˚F)200˚C(
Electromechanical dataCable entry/plug (dependent on the version)- Single chamber housingl 1x cable entry M20x1.5 (cable-ø 5 … 9 mm),1x blind stopper
9.2 DimensionsOPTISWITCH 3100 C112mm(4 13/32")117mm(4 39/64")114mm(4 31/64")~ 69mm(2 23/32")ø 77mm(3 1/32")~ 69mm(2 23/32&quo
9 Supplement9.1 Technical data...269.2 Dimensions ...29Supplementary operating instructions manualsInfor
22mm(55/64")33mm(1 19/64")220mm (8 21/32")150mm (5 29/32")G1½Aø 43mm (1 11/16")Fig. 17: OPTISWITCH 3100 C, threaded version G
178mm (7 1/64")ø 34mm (1 11/32")Fig. 18: Temperature adapterSupplementOPTISWITCH 3100 C - with contactless electronic switch 3129952-EN-0608
Subject to change without notice29952-EN-060830
1 About this document1.1 FunctionThis operating instructions manual has all the information youneed for quick setup and safe operation. Please read th
2 For your safety2.1 Authorised personnelAll operations described in this operating instructions manualmust be carried out only by trained specialist
2.6 SIL conformityOPTISWITCH 3100 C fulfills the requirements of functionalsafety according to IEC 61508/IEC 61511. You can find furtherinformation in t
3 Product description3.1 ConfigurationThe scope of delivery encompasses:l OPTISWITCH 3100 C level sensorl Documentation- this operating instructions ma
It functions even when exposed to strong external vibration orchanging products.Solid detection in waterIf OPTISWITCH 3100 C was ordered for detection
l potentiometer for adaptation to the product densityl Mode switch for selecting the switching condition (min./max.)3.4 Storage and transportYour inst