Addendum for hazardous areas. These additional instructions are an extension to the OPTISONIC 6300 quick start and handbookOPTISONIC 6300OPTISONIC 630
1 INTRODUCTION 10 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 enThe typeplates of the FM approved flowmeters look simila
TEMPERATURE LIMITS 211OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en2.1 GeneralDue to the influence of the process temp
2 TEMPERATURE LIMITS 12 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en2.2 UFC 300 F(/i)-ExThe UFC 300 F(/i)-Ex ultrason
CONNECTION OF SEPARATE SYSTEMS 313OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en3.1 GeneralThe electrical connection be
3 CONNECTION OF SEPARATE SYSTEMS 14 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en3.5 Signal cable connectionsSee the p
CONNECTION OF SEPARATE SYSTEMS 315OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 enFigure 3-3: Construction (field version)
4 ELECTRICAL CONNECTIONS 16 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en4.1 GeneralThe display cover seals the electr
ELECTRICAL CONNECTIONS 417OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 enThe exact I/O-configuration for circuits A, B, C
4 ELECTRICAL CONNECTIONS 18 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en4.2 Non-"Ex i" I/O connectionsThe f
ELECTRICAL CONNECTIONS 419OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en4.3 "Ex i" I/O connectionsThe followi
CONTENTS 2 www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 enOPTISONIC 63001 Introduction 31.1 Safety instructions from the manufactur
4 ELECTRICAL CONNECTIONS 20 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 enINFORMATION!For converters with an “Ex e” term
MAINTENANCE 521OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en5.1 MaintenanceThe flowmeters are maintenance free with re
5 MAINTENANCE 22 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en5.3 Replacement of mains fuse• Pull the display unit of
MAINTENANCE 523OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en5.4 Exchange of electronics unitBefore opening the convert
5 MAINTENANCE 24 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en5.4.1 Field versionPerform the following procedures:• U
MAINTENANCE 525OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en• Remove the printed circuit board 6 from the electronics
5 MAINTENANCE 26 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en5.5 Service / repair informationThis device has been car
MAINTENANCE 527OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en5.6 Form (for copying) to accompany a returned device5.7
KROHNE product overview• Electromagnetic flowmeters• Variable area flowmeters• Ultrasonic flowmeters• Mass flowmeters• Vortex flowmeters• Flow control
INTRODUCTION 13OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en1.1 Safety instructions from the manufacturer1.1.1 Copyri
1 INTRODUCTION 4 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en1.1.3 Product liability and warrantyUltrasonic flowmeter
INTRODUCTION 15OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en1.1.5 Warnings and symbols usedSafety warnings are indicat
1 INTRODUCTION 6 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 enFor information, maintenance or service please contact yo
INTRODUCTION 17OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en1.3 ApprovalThe ultrasonic flowmeters are manufactured acc
1 INTRODUCTION 8 OPTISONIC 6300www.krohne.com 03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en1.5 UFC 300 F(/i)-ExThe UFC 300 F(/i)-Ex is the separate
INTRODUCTION 19OPTISONIC 6300www.krohne.com03/2010 - 7309972300 - EX OPTISONIC 6300 R03 en1.6 Marking labelsSee the marking labels (i.e. data sticke
Comments to this Manuals