2-wire / 10 GHz Radar (FMCW) Level Meterfor distance, level, volume, flow and reflection measurement of liquids, pastes and slurriesOPTIWAVE 5200 C/FO
1 SAFETY INSTRUCTIONS 10 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1.4.2 U.S.A. and CanadaThis legal information
8 TECHNICAL DATA 100 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en"TBF Partial" mode"TBF Partial"
TECHNICAL DATA 8101OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en8.2 Technical dataINFORMATION!•The following data is
8 TECHNICAL DATA 102 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enBeam angle (½ angle) of antenna PP Wave Horn: 10°PT
TECHNICAL DATA 8103OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enPressurePressurePressurePressureProcess pressure PP W
8 TECHNICAL DATA 104 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enProcess connectionsThread PP Wave Horn antenna: G 1
TECHNICAL DATA 8105OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enFOUNDATIONFOUNDATIONFOUNDATIONFOUNDATION™ fieldbus fi
8 TECHNICAL DATA 106 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enATEX (Ex ic)DEKRA 13ATEX0051 XCompact versionCompac
TECHNICAL DATA 8107OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enNEPSI Ex ia IIC T2~T6 Gb or Ex ia IIC T2~T6 Ga/Gb DIP
8 TECHNICAL DATA 108 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en8.3 Minimum power supply voltageUse these graphs t
TECHNICAL DATA 8109OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en8.4 Pressure ratingsWARNING!Make sure that the devic
SAFETY INSTRUCTIONS 111OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1.5 Safety instructions from the manufacturer1.5
8 TECHNICAL DATA 110 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enISO threaded connections: PP Wave Horn antennaFigur
TECHNICAL DATA 8111OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enASME flanges: Metallic Horn, Wave Guide and PTFE Wave
8 TECHNICAL DATA 112 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enINFORMATION!CRN CERTIFICATIONThere is a CRN certifi
TECHNICAL DATA 8113OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enASME threaded connections: PP Wave Horn antennaFigure
8 TECHNICAL DATA 114 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enINFORMATION!CRN CERTIFICATIONThere is a CRN certifi
TECHNICAL DATA 8115OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en8.5 Antenna selectionThe graphs below show which ant
8 TECHNICAL DATA 116 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en8.6 Dimensions and weightsHousing, process connect
TECHNICAL DATA 8117OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enHousing options: Dimensions in mm and inchesProcess c
8 TECHNICAL DATA 118 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enSpecial antenna extensions: Dimensions in mmSpecial
TECHNICAL DATA 8119OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enPurging system and heating/cooling system: Dimensions
1 SAFETY INSTRUCTIONS 12 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1.5.3 Product liability and warrantyThe operat
8 TECHNICAL DATA 120 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enDimensions and weights in mm and kgDimensions and w
TECHNICAL DATA 8121OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enConverter and antenna housing weightsAntenna option w
8 TECHNICAL DATA 122 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enOther optionsOther optionsOther optionsOther option
DESCRIPTION OF HART INTERFACE 9123OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en9.1 General descriptionThe HART® Prot
9 DESCRIPTION OF HART INTERFACE 124 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en9.3 Connection variantsThe signal c
DESCRIPTION OF HART INTERFACE 9125OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en9.5 Field Communicator 375/475 (FC 37
9 DESCRIPTION OF HART INTERFACE 126 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enFor installation data, refer to the
DESCRIPTION OF HART INTERFACE 9127OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enFor more data, refer to “readme.txt”.
9 DESCRIPTION OF HART INTERFACE 128 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en9.9.2 Basic-DD menu tree (details f
DESCRIPTION OF HART INTERFACE 9129OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en9.10 HART® menu tree for AMSAbbreviat
SAFETY INSTRUCTIONS 113OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1.5.5 Warnings and symbols usedSafety warnings a
9 DESCRIPTION OF HART INTERFACE 130 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en9.10.2 AMS menu tree (details for s
DESCRIPTION OF HART INTERFACE 9131OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en9.11 HART® menu tree for PDMAbbreviat
9 DESCRIPTION OF HART INTERFACE 132 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enOverview: PDM parameters9.11.2 PDM
DESCRIPTION OF HART INTERFACE 9133OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enView MenuAccess rightsAccess levelRdMe
10 APPENDIX 134 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en10.1 Order codeMake a selection from each column to get
APPENDIX 10135OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enPressure / Temperature / Sealing (higher flange temperatur
10 APPENDIX 136 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enMaterial and Antenna extensionMaterial and Antenna exten
APPENDIX 10137OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enJIS B2220 FlangesH U P 10K 50A RF 7L U P 10K 80A RFM U P 1
10 APPENDIX 138 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enDisplay languageDisplay languageDisplay languageDisplay
APPENDIX 10139OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enExtra optionExtra optionExtra optionExtra option0 Without1
2 DEVICE DESCRIPTION 14 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en2.1 Scope of deliveryINFORMATION!Do a check of
10 APPENDIX 140 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en10.2 Spare partsWe supply spare parts for this device.
APPENDIX 10141OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enMaterial and Antenna extensionMaterial and Antenna extensi
10 APPENDIX 142 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enJIS B2220 FlangesH U P 10K 50A RF 4L U P 10K 80A RFM U P
APPENDIX 10143OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enOther spare partsFigure 10-1: Other spare parts1 Cover wi
10 APPENDIX 144 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en10.3 AccessoriesWe supply accessories for this device.
APPENDIX 10145OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en10.4 GlossaryDEFHILMDead zoneDead zoneDead zoneDead zone
10 APPENDIX 146 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enOPRSTUVWOperatorsOperatorsOperatorsOperators Users who c
APPENDIX 10147OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enFigure 10-3: Measurement definitions: distance1 Distance2
KROHNE product overview• Electromagnetic flowmeters• Variable area flowmeters• Ultrasonic flowmeters• Mass flowmeters• Vortex flowmeters• Flow control
DEVICE DESCRIPTION 215OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en2.2 Device descriptionThe FMCW radar level transm
2 DEVICE DESCRIPTION 16 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enIf the process connection temperature is more th
DEVICE DESCRIPTION 217OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en2.3 Visual CheckIf the device is supplied with an
2 DEVICE DESCRIPTION 18 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en2.4 Nameplates2.4.1 Nameplate (examples)INFORM
INSTALLATION 319OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en3.1 General notes on installation3.2 Storage• Store th
All rights reserved. It is prohibited to reproduce this documentation, or any part thereof, without the prior written authorisation of KROHNE Messtech
3 INSTALLATION 20 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en3.3 Transport3.4 Pre-installation requirements• Make
INSTALLATION 321OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en3.5 Installation3.5.1 Pressure and temperature rangesF
3 INSTALLATION 22 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enThere is no change (de-rating) in ambient temperature
INSTALLATION 323OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en3.5.2 Recommended mounting positionCAUTION!Follow these
3 INSTALLATION 24 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enPoint the device in the correct directionFigure 3-6: P
INSTALLATION 325OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en3.5.3 Mounting restrictionsWe recommend that you prepar
3 INSTALLATION 26 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enObstacles in the tankFigure 3-10: Obstacles in the tan
INSTALLATION 327OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enThe antenna must project out of the nozzle. If necessary
3 INSTALLATION 28 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enEquipment needed:• Device• Flange gasket (not supplied
INSTALLATION 329OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enEquipment needed:• Device• Gasket for G 1½ connection (n
CONTENTS 3www.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enOPTIWAVE 5200 C/F1 Safety instructions 71.1 Software history ...
3 INSTALLATION 30 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en3.5.4 Standpipes (stilling wells and bypass chambers)
INSTALLATION 331OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enStilling wells - general notesInstallation in tanks cont
3 INSTALLATION 32 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enStilling wells: floating roofsIf the device must be in
INSTALLATION 333OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enStilling wells: horizontal cylindrical tanksWe recommend
3 INSTALLATION 34 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enBypass chambersInstallation next to tanks containing o
INSTALLATION 335OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en3.5.6 How to attach an antenna extension (Metallic Horn
3 INSTALLATION 36 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enProcedure 1: How to attach an antenna extension1 Remo
INSTALLATION 337OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enantenna extension, "S" antenna extension or &q
3 INSTALLATION 38 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en3.5.8 How to attach the weather protection to the dev
INSTALLATION 339OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1 Remove the 2 butterfly screws from the housing. Make
CONTENTS 4 www.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enOPTIWAVE 5200 C/F4 Electrical connections 424.1 Safety instructions...
3 INSTALLATION 40 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enThe overall dimensions of the weather protection are o
INSTALLATION 341OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en3.5.9 How to open the weather protection1 Loosen the b
4 ELECTRICAL CONNECTIONS 42 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en4.1 Safety instructionsDANGER!All work on t
ELECTRICAL CONNECTIONS 443OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en4.2 Electrical installation: 2-wire, loop-pow
4 ELECTRICAL CONNECTIONS 44 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en• Loosen the lock screw with a 2.5 mm Allen
ELECTRICAL CONNECTIONS 445OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en• Put the cover on the housing and push it do
4 ELECTRICAL CONNECTIONS 46 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en4.3 Remote device data4.3.1 Requirements f
ELECTRICAL CONNECTIONS 447OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en4.3.2 How to prepare a signal cable supplied
4 ELECTRICAL CONNECTIONS 48 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1 Remove the PVC jacket from the wire to di
ELECTRICAL CONNECTIONS 449OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enEquipment neededFigure 4-8: Equipment needed t
CONTENTS 5www.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enOPTIWAVE 5200 C/F6.5 Status and error messages...
4 ELECTRICAL CONNECTIONS 50 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1 Remove the terminal compartment cover.2
ELECTRICAL CONNECTIONS 451OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1 Remove the terminal compartment cover.2 Re
4 ELECTRICAL CONNECTIONS 52 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en4.4 Electrical connection for current outpu
ELECTRICAL CONNECTIONS 453OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en• Make sure that the gaskets are not damaged.
4 ELECTRICAL CONNECTIONS 54 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en4.6.3 Multi-drop networksFigure 4-15: Multi
ELECTRICAL CONNECTIONS 455OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en4.6.4 Fieldbus networksFor more data, refer t
4 ELECTRICAL CONNECTIONS 56 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enPROFIBUS PA/DP network (non-Ex)Figure 4-17:
START-UP 557OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en5.1 How to start the device5.1.1 Start-up checklistCheck t
5 START-UP 58 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en5.3 Digital display screen5.3.1 Local display screen lay
START-UP 559OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en5.3.2 Functions of keypad buttonsFor data on keypad functio
CONTENTS 6 www.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enOPTIWAVE 5200 C/F9.9 HART® menu tree for Basic-DD ...
5 START-UP 60 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enInstall these software programs and equipment:• Microsoft®
OPERATION 661OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.1 User modes6.2 Normal modeThis mode shows measurement
6 OPERATION 62 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enMeasurement type definitions6.3 Configuration mode6.3.1
OPERATION 663OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.3.2 How to get access to the commissioning menuThe commi
6 OPERATION 64 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.3.3 Keypad functionsThis is what you see when you are
OPERATION 665OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enThis is what you see when you select a menu item that has a
6 OPERATION 66 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enThis is what you see when you select a menu item that has
OPERATION 667OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.3.4 Menu overview1.0.0 Info. (Information)1.1.0 Ident. (
6 OPERATION 68 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.3.5 Function description1.0.0 Information (Info.) menu
OPERATION 669OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en2.0.0 Supervisor menuMenu No.Function Function description
SAFETY INSTRUCTIONS 17OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1.1 Software history"Firmware revision"
6 OPERATION 70 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en2.2.2 DIAGNOSTIC This starts the hardware test. Push [>
OPERATION 671OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en2.3.5 STILLWELL D. The inner diameter of the stilling well.
6 OPERATION 72 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en2.5.0 APPLICATION2.5.1 TANK TYPE The conditions in which
OPERATION 673OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en2.5.7 EMP.SPEC.EN. The supervisor can start or stop the emp
6 OPERATION 74 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en3. Service menu4. Master menu2.9.0 CONFIG/RESET2.9.1 SAVE
OPERATION 675OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.4 Further information on device configuration6.4.1 Quic
6 OPERATION 76 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en• [] or [] for the selection of the current outpu
OPERATION 677OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.4.2 TestUse this procedure to test the loop current. « x
6 OPERATION 78 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.4.3 Protection of the device settingsThe menu item PAS
OPERATION 679OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enHow to change from multidrop to point-to-point mode• Enter
1 SAFETY INSTRUCTIONS 8 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1.3 CertificationIn accordance with the commitm
6 OPERATION 80 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.4.6 Level measurementThe device displays level measure
OPERATION 681OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.4.7 How to configure the device to measure volume or mas
6 OPERATION 82 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enHow to delete a volume or mass table.• Enter the supervi
OPERATION 683OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en• After you enter the supervisor menu, push 2 × [>>&
6 OPERATION 84 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.5 Status and error messages6.5.1 Device status (marke
OPERATION 685OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enIf an "Out of specification" or a "Maintenan
6 OPERATION 86 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en6.5.2 Error handlingHow to find an error record• Push [
OPERATION 687OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enERR 103 Converter memory failure1 The device's hardwar
6 OPERATION 88 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enOut of specification (NE 107 status signal)ERR 102 Temper
OPERATION 689OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en_ Temperature >+75°C / +167°F3 The ambient temperaure is
SAFETY INSTRUCTIONS 19OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enAccording to ETSI EN 302 372 (2006-04), the radiat
7 SERVICE 90 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en7.1 Periodic maintenanceNo maintenance is necessary. If it
SERVICE 791OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enHow to use the purge7.3 Heating or cooling horn antennas und
7 SERVICE 92 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en• Remote (field) version:Remote (field) version:Remote (fie
SERVICE 793OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en4 Give the password for the SERVICE menu. If you do not have
7 SERVICE 94 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en1 Make sure that the gasket is on the flange connection.2
SERVICE 795OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 enProcedure 4: How to set the correct offset value (OPTIWAVE 52
7 SERVICE 96 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en7.7 Returning the device to the manufacturer7.7.1 General
SERVICE 797OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en7.7.2 Form (for copying) to accompany a returned deviceCompa
7 SERVICE 98 OPTIWAVE 5200 C/Fwww.krohne.com 07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en7.8 DisposalCAUTION!Disposal must be carried out in accord
TECHNICAL DATA 899OPTIWAVE 5200 C/Fwww.krohne.com07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en8.1 Measuring principleA radar signal is emitted via
Comments to this Manuals